For more information, contact Abbott.
For more information, contact Abbott.
PRODUCT NAME | UNIT SIZE | ORDER NUMBER | GTIN |
---|
Abbott RealTime IDH2 is an in vitro polymerase chain reaction (PCR) assay for the qualitative detection of single nucleotide variants (SNVs) coding nine IDH2 R140 and R172 mutations (R140Q, R140L, R140G, R140W, R172K, R172M, R172G, R172S, and R172W) in DNA extracted from human bone marrow (EDTA collection tubes) or blood (EDTA collection tubes).
Abbott RealTime IDH2 is for use with the Abbott m2000rt System. Abbott RealTime IDH2 consists of two kits:
Intended Use
Abbott RealTime IDH2 is an in vitro polymerase chain reaction (PCR) assay for the qualitative detection of single nucleotide variants (SNVs) coding nine IDH2 R140 and R172 mutations (R140Q, R140L, R140G, R140W, R172K, R172M, R172G, R172S, and R172W) in DNA extracted from human blood (EDTA) or bone marrow (EDTA). Abbott RealTime IDH2 is for use with the Abbott m2000rt System.
Indications For Use
Abbott RealTime IDH2 is indicated as an aid in identifying acute myeloid leukemia (AML) patients with an isocitrate dehydrogenase-2 (IDH2) mutation for treatment with IDHIFA® (enasidenib).
Assay Protocol
The Abbott RealTime IDH2 assay protocol includes the following steps:
Specimens for Abbott RealTime IDH2 are processed manually using Abbott mSample Preparation SystemDNA (List No. 06K12 24) reagents to isolate and purify sample DNA.
The Abbott RealTime IDH2 amplification reagents are combined into four amplification master mixes.
The purified DNA sample is combined with the master mixes in an Abbott 96-Well Optical Reaction Plate, and the plate is transferred to the Abbott m2000rt instrument for amplification and detection of IDH2 mutations.
The specimen result is automatically reported on the Abbott m2000rt workstation at run completion. Assay controls are included within each run and are processed through the DNA extraction, amplification, and detection steps of the assay to assess run validity.
Software parameters specific to Abbott RealTime IDH2 are contained in an assay application specification file, which is loaded onto the Abbott m2000rt instrument by using a CD ROM disk.
Refer to the Warnings and Precautions section of the package insert for instructions before preparing samples.
Limitations of the Assay
To learn more about RealTime IDH2 please visit: https://www.molecular.abbott/int/en/realtime-idh2
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.
Please be aware that the website you have requested is intended for the residents of a particular country or countries, as noted on that site. As a result, the site may contain information on pharmaceuticals, medical devices and other products or uses of those products that are not approved in other countries or regions.